3. Mounting the Faucet
A. Pre-assemble the base. The rubber washer should be
in place below the base. The two toggle bolts should be
inserted through the base and the rubber washer. The
bolts are screwed into the spring-loaded toggle.
B. Place the base assembly over the hole in the sink. The
two toggles should pass through the hole far enough to
spring fully open. If they are not open, unscrew the bolt
until the toggle moves down to clear the sink.
C. Look down through the base for this step. Before
tightening the bolts, determine the correct rotation of the
off from the bolt heads. Use Figure 5 to help determine
the best position for your installation.
Through the hole in the base, hold the toggle in position
while tightening the bolt. The spring loaded toggle
will contact the bottom of the counter top and hold in
position. Do not fully tighten. Repeat for second toggle
bolt.
Tighten the two bolts evenly. DO NOT OVERTIGHTEN.
Tighten only far enough to prevent the base from
rotating when the faucet is rotated in place.
D. Attach large diameter 3/8" (red) drain tube to the larger
long enough to reach the drain clamp in Step 7.
E. Locate the 1/4" red brine tube from the right side of the
system head assembly. Route the tube through the
faucet base and connect to small barb on the faucet.
Make certain that the tube is not kinked or stressed
once the head assembly is mounted.
F.
quick connector onto end of threads.
G. Wet end of 3/8" blue tube. Push into bottom of
connector. Tug gently to be sure connection is
complete. This tube should be long enough to reach the
top right side of the RO Assembly.
H. Check that the O-ring is in place on the faucet. Feed
the remaining 3/8" tubes through the base. Hold the
left) while pushing down. The faucet will drop into the
base. Push down on the faucet and rotate forward (to
seated and the faucet held securely in position.
I. Insert the spout into the top opening. Hold in position
and screw the collar onto the base.
NOTE: If the faucet handle is not in the correct
position, remove the faucet, loosen the toggle
bolts and reposition the base. Tighten the
toggle bolts. Then reinstall the faucet.
Base
Black Rubber
Washer
Folds Upward
A
Figure 3
B
Base
Black Rubber
Washer
Will Spring Open
O-ring Seat
Figure 4
C
Handle Faces This Direction
45°
Notch For Faucet
Blades Must Be Held
When Tightening
Notch For Faucet
Figure 5
G
D
E
F
Figure 6
INSTALLATION continued
O-ring
4 • HP-RO-1000 Undersink Reverse Osmosis System
Page view 3
1 2 3 4 5 6 7 8 9 ... 15 16

Comments to this Manuals

No comments